• Home
  • Alle
  • Updates für Inventor 2014 und Vault 2014 verfügbar

Updates für Inventor 2014 und Vault 2014 verfügbar

  Für den Inventor 2014 gibt es das Update 2

Das Update 2 beinhaltetet das Update 1 =>
Somit ist es nur mehr nötig das Update 2 zu installieren.

DL21901957.zip (zip – 19243Kb)  Was wurde behoben im Update 2?

  • Older VBA code is not working properly
  • Shaded views are not showing correct in drawing with zoom
  • Inconsistant behavior when Copy and Paste of components where file path is long
  • Layout constraint context menu command is missing
  • One side of brake line show unshaded when creating break in a shaded projected view
  • Bolted connection is not able to machine more than two parts at the same time
  • Unexpected exit when Loading idw
  • Stability enhancement

 

nach der Installation wird im Info Dialog der neue Stand angezeigt. (Update 2)

  • IV     Für den Vault gibt es das Service Pack 1   Smiley dies ist vom Downloadvolumen etwas größer Smiley
    AutodeskVault_2014_ServicePack1.zip (zip – 713401Kb)
    Nach dem Update werden auch diese Information im Info Dialog angezeigt. image

    Obwohl das Update Service Pack heißt auf der Download-Homepage wird es im Info Dialog als Update 1 angezeigt. => Also nicht verwirren lassen. Smiley

    Hier wurde eine ganze Liste behoben: (siehe unten) Warum nicht nur der Vault Server und der Vault Client betroffen ist, liegt daran, dass auch das AutoCAD / Inventor/ Revit Add In mit Upgedatet wird. WICHTIG: Vault Updates sind nicht so trivial wie AutoCAD oder Inventor Updates. Hier muss man genau wissen was zu tun ist.
    ! Es geht um die gesamten Daten!
    ADMS – Server:

    1. Improved server performance for connected workgroup (full database replication).
    2. Inside the ADMS Console on the Replicated Folders dialog, resolved the issue of not honoring the folder checkbox.

    Client:

    1. Improperly displaying an ownership error when the user exits an Administration dialog on the Vault Client when the current workgroup does not have the Administration token.
    2. Not able to download iLogicVB files from Vault.
    3. Fixed empty node shown when expand/collapse the Project Explorer view panel.
    4. Fixed error viewing file when Autodesk Design Reviewer 2013 is not installed.
    5. After renaming, Get / Check out of AutoCAD Electrical files with Parents throws Update file reference error.
    6. Cannot Print ECO Summary with IE9 installed.
    7. Find and Clear buttons overlap in the Find panel of View tab of Item Master as well as  in the Files tab of Change Order List.
    8. Inventor property ‚Doc Sub Type Name‘ is being extracted when mapped to an Item User Defined Property.
    9. Missing images at Items Export and Import dialogs are resolved.
    10. Fixed viewing of AutoCAD Electrical Files/DWF in Vault Explorer on x64 machines.
    11. AutoCAD properties configured with a bi-direction mapping will not update when performing some ‚update properties‘ workflows (especially API calls).
    12. Impossible to choose another device in the Plot Manager when plotting PDF files.
    13. IExplorerUtil.UpdateFileProperties did not update mapped AutoCAD properties.
    14. Fixed error ‚No Open Entry‘ while doing Pack-And-Go on file set containing parts of same file name (different content) but residing in different folder(s).
    15. When using the Assign or Update Item dialogs to update items, only the first level children may show up in the assign item wizard, even though other children are in need of updating before Items can be released.
    16. Visualization Publish Options do not work as expected when performing Update View on AutoCAD Mechanical and Electrical drawings.
    17. Unable to plot DWF format on 64-bit OS.
    18. Cannot write back properties to .DOC files.
    19. Emails from Outlook are not getting Checked into Vault when multiple Check-in operations happen simultaneously.
    20. CER: Get/Checkout of file with a direct parent that is cloaked throws Error dialog.

    AutoCAD:

    1. Corrected ‚Search Results‘ node behaviour in AutoCAD Open From Vault dialog.

    Inventor:

    1. Children files are not getting downloaded from Vault if they are already in the local disk​.
    2. „Close All“ command is not Checking in all the opened files​.
    3. Incorrect Vault status for the Substitute LOD parts coming in from Library Project​.
    4. Open from Vault Icon is not sticky in the Inventor Quick Access Toolbar​.
    5. Unloading Vault add-in and restarting Inventor will show 2 Vault tabs in the ribbon for a new document​.
    6. Open from Vault is opening wrong revision of the Drawing if the corresponding Assembly is opened already.
    7. Added ‚Rename/Delete‘ function for Shortcuts listed in Inventor Open From Vault Dialog.
    8. File dirty flag is not shown for Non vaulted files in Inventor
    9. Transparency setting for Inventor icon is not showing properly in Vault browser on Windows 8
    10. Manual refresh is needed to show the correct Vault status.
    11. CER: Unexpected exit of Inventor when suppressing or unsupressing parts​.

    Revit:

    1. Delete target Vault folder before completing „Add Files“, no error is displayed.
    2. Back and Up buttons are not working as expected in Load Family dialog.
    3. Browsing into a file via the right pane still shows the .rfa icon for family types.
    4. Clearing family search filters quickly, leaves you stuck in search results.
    5. Windows classic theme breaks search button.
    6. Revit Login error dialog indicates wrong Revit version.
    7. After Closing main file and saying Yes to the SaveToVault prompt  the main file remains checked out from Vault.
    8. Error comes when user wants to add read-only files to vault.
    9. „Add Files“ to invalid vault folder results in incorrect, non-modal error message.
    10. Restrictions dialog is not modal while using Add Folder option with a file in that folder is still open in Revit.
    11. Getting an extra prompt when uploading a network shared central file, where the mapping is referenced by a local mapped drive letter as opposed to a UNC path.
    12. Linked files do not appear in Load Family dialog.
    13. Fixed by removing „Family Type Already Exists“ dialog  while adding an existing Family Type.
    14. Fixed the UI of “File Extensions” part in Options Dialog.
    15. While working on any canvas, user can see link file’s content in host file when the link file is from vault.
    16. Provide the function of search by Family file name.

    Others:

    1. Resolved the following Autodesk Reference Repair Utility issues;
      • „Some files could not be processed due to errors“ message.
      • „The utility has encountered some errors and it has stopped working“ message.
      • Localized versions of Vault server without a default ‚Administrator‘ account was causing login to fail.
      • Logging into a Vault server with IIS running on a port other than 80 was causing login to fail.
    2. Inside the Reference Repair Utility, the settings options have been disabled to reflect that the user cannot do anything post an execution of the utility.
    3. In the Reference Repair Utility, fixed the consistency issue by ensuring that even null value UDPs are written to the XML as empty.
    4. For Vault properties mapped to a custom office file property, the Update Properties toolbar button may be inactive when accessing Office files on subscriber ADMS instances.
    5. Autodesk Vault icon is disabled in MS Office and Outlook 2007.
    6. Performance improvement for dragging and dropping larger number of files to vault.
    7. Check In from Outlook will return warning when a previous Check In is in progress.

Related Posts

  ist verfügbar und kann hier heruntergeladen werden: INV18210.zip (zip - 9.65Mb) Readme

Seit letzte Woche Freitag ist das SP1 für Inventor 2014 verfügbar. Wer brav seine Fehlerberichte

Vor der Installation des SP´s wird empfohlen das SP1 für Navisworks zu installieren! Hier der Lin

    Hotfix INV18201 for Inventor 2014 Service Pack 2 INV18201.zip (zip - 576.06Kb)

  Gibt es eine einfache und schnelle Möglichkeit Linienstärken (und Farben) abhängig von Ko

LEAVE YOUR COMMENTS